These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Transesophageal 3-dimensional echocardiography: in vivo determination of left ventricular mass in comparison with magnetic resonance imaging.
    Author: Kühl HP, Bücker A, Franke A, Maul S, Nolte-Ernsting C, Reineke T, Hoffmann R, Günther RW, Hanrath P.
    Journal: J Am Soc Echocardiogr; 2000 Mar; 13(3):205-15. PubMed ID: 10708469.
    Abstract:
    The objective of this study was to assess the accuracy and reproducibility of transesophageal 3-dimensional echocardiography (3DE) in comparison with magnetic resonance imaging (MRI) for the in vivo calculation of left ventricular mass (LVM). In addition, mass values obtained by M-mode echocardiography were compared with those calculated by MRI. Three-dimensional reconstruction of the left ventricle was performed from a transesophageal and transgastric transducer position with a multiplane transducer in 20 patients. Left ventricular mass was calculated from both transducer positions by using slices of various thicknesses, ranging from 5 to 20 mm. Reproducibility was determined by 5 repeated measurements of mass in each of 5 randomly selected left ventricles. M-mode echocardiography was performed according to the method described by Devereux. For MRI, multiple short-axis views with 10-mm slice thickness were acquired in inspiration hold. Correlation was high for mass determined by 3DE and MRI (for 10-mm slice thickness: r = 0.99; y = 0.99 x - 0.7 g; standard error of estimate = 8.5 g; P <.001). There was no statistical bias, and the limits of agreement ranged from +/-16.4 g to +/-27.2 g, depending on the slice thickness. Variability was lowest for a slice thickness of 10 mm (SD +/- 8.2 g). The reproducibility of mass determination was excellent (mean width of the 95% CI 12.8 g). Left ventricular mass values calculated from the transgastric and transesophageal transducer position were not different from each other (mean bias 0.6 +/- 9.1 g; P = ns). M-mode-based LVM calculations showed systematic overestimation and large measurement variability (bias 23.7 g; 95% CI +/- 92.8 g). Compared with MRI, transesophageal 3DE is an accurate and reproducible method for the determination of LVM and clearly superior to M-mode echocardiography.
    [Abstract] [Full Text] [Related] [New Search]