These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Tubeless combined high-frequency jet ventilation for laryngotracheal laser surgery in paediatric anaesthesia. Author: Ihra G, Hieber C, Adel S, Kashanipour A, Aloy A. Journal: Acta Anaesthesiol Scand; 2000 Apr; 44(4):475-9. PubMed ID: 10757585. Abstract: BACKGROUND: High-frequency jet ventilation (HFJV) is an alternative ventilatory approach in airway surgery and for facilitating gas exchange in patients with pulmonary insufficiency. We have developed a new technique of combined HFJV utilising two superimposed jet streams. In this study we describe the application of tubeless supralaryngeal HFJV during laryngotracheal laser surgery in infants and children. METHODS: Tubeless combined HFJV characterised by the simultaneous supralaryngeal application of a low-frequency (LF) and a high-frequency (HF) jet stream was evaluated in a clinical study in 10 children undergoing elective laryngotracheal CO2 laser surgery. Additionally, pressure and flow characteristics were determined with the use of a paediatric test lung. HFJV was applied by means of a modified Kleinsasser laryngoscope with integrated metal injectors. In addition to pulse oximetry, monitoring of ECG, heart rate and blood pressure, supraglottic airway pressure was measured and arterial blood gases were analysed. RESULTS: Tubeless combined HFJV was used in 10 infants and children (mean age 4.6 yr, range 2 months-10 years) undergoing 17 consecutive endoscopic procedures with CO2 laser microsurgery of the larynx or the trachea under general anaesthesia. The mean duration of supralaryngeal HFJV was 46 min (range 15-75 min). Mean driving pressures of the HF and the LF jet streams were 0.75 bar and 0.95 bar, respectively. Inspiratory oxygen ratios were in the range 0.4-1.0. HFJV resulted in mean PaO2 and PaCO2 values of 19.7 kPa and 6.1 kPa, respectively. No complications during HFJV were observed. In the test lung, combined HFJV applied with driving pressures of 0.7-1.0 bar and 0.9-1.2 bar for HF and LF jet ventilation, respectively, resulted in maximum peak and baseline distal airway pressures of 17.6 cm H2O and 5.4 cm H2O, respectively. CONCLUSION: The application of the combined double frequency HFJV was effective in maintaining gas exchange in the presence of laryngeal or tracheal stenoses. It provided good visibility of anatomical structures and offered space for surgical manipulation, avoiding the use of combustible material inside the larynx or trachea.[Abstract] [Full Text] [Related] [New Search]