These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Airway complications in infants: comparison of laryngeal mask airway and the facemask-oral airway.
    Author: Harnett M, Kinirons B, Heffernan A, Motherway C, Casey W.
    Journal: Can J Anaesth; 2000 Apr; 47(4):315-8. PubMed ID: 10764174.
    Abstract:
    PURPOSE: To compare the incidence of airway complications in children less than one year of age whose airways were maintained during anesthesia with either a laryngeal mask airway (LMA) or a facemask and oral airway (FM-OA). METHODS: We randomized 49 - ASA class 1&2 - infants to an LMA or FM-OA group. All infants were undergoing minor general, urological or orthopedic procedures. Anesthesia was induced and maintained with halothane in nitrous oxide 50% and oxygen. The airway was removed in both groups when the infant was awake. The occurrence of airway complications (breath-holding, coughing, laryngospasm, secretions, obstruction and oxygen saturation < 95%) at induction of anesthesia, intraoperatively and during emergence from anesthesia was recorded. RESULTS: Airway complications occurred perioperaively in 15 of 27 infants in the LMA group and in 5 of 22 infants in the FM-OA group (P: 0.02). CONCLUSION: In infants, the use of the LMA is associated with an increased incidence of airway complications compared with the use of the FM-OA.
    [Abstract] [Full Text] [Related] [New Search]