These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Strategy for optimal aortic regurgitation quantification by Doppler echocardiography: agreement among different methods.
    Author: Evangelista A, del Castillo HG, Calvo F, Permanyer-Miralda G, Brotons C, Angel J, González-Alujas T, Tornos P, Soler-Soler J.
    Journal: Am Heart J; 2000 May; 139(5):773-81. PubMed ID: 10783209.
    Abstract:
    BACKGROUND: Although different Doppler methods have been validated for aortic regurgitation quantification, the benefit of combining information from different methods has not been defined. METHODS: Our study included 2 phases. In the initial phase (60 patients), Doppler parameters (jet width, short-axis jet area, apical jet area, regurgitant fraction from pulmonary and mitral flow, and deceleration slope) were correlated with angiography; range values for each severity grade were defined and intraobserver and interobserver and intermachine variability were studied. In the validation phase (158 patients), defined value ranges were prospectively tested and a strategy based on considering as the definitive severity grade that in which the two best methods agreed was tested. RESULTS: Jet width had the best correlation with angiography (r = 0.91), and its ratio with the left ventricular outflow diameter did not improve the correlation (r = 0.85) and decreased reproducibility. Apical jet area and regurgitant fraction from pulmonary flow permitted acceptable quantification (r = 0.87 and 0.86, respectively) but with worse reproducibility. The other methods were not assessable in 20% to 30% of studies. Concordance with angiography decreased in jet width when the jet was eccentric (90% vs 77%, P <.01), in apical jet area when mitral valve disease was present (84% vs 65%, P <.02), and in short-axis jet area and regurgitant fraction from pulmonary flow with concomitant aortic stenosis (77% vs 44%, P <.002 and 77% vs 53%, P <.02, respectively). Agreement with angiography was very high (94 [95%] of 99) when severity grade coincided in both jet width and apical jet area. In 59 cases without concordance, regurgitant fraction from pulmonary flow was used as a third method. Overall, this strategy permitted concordance with angiography in 146 patients (92%). CONCLUSIONS: Jet width is the best predictor in aortic regurgitation quantification by Doppler echocardiography. However, better results were obtained when a strategy based on concordance between jet width and another Doppler method was established, particularly when the jet was eccentric.
    [Abstract] [Full Text] [Related] [New Search]