These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Implantable loop monitor for detection of syncope. Author: Cerino-Toth L. Journal: Crit Care Nurs Clin North Am; 1999 Sep; 11(3):297-301. PubMed ID: 10786476. Abstract: A precise correlation of patient symptoms and rhythm disturbances is a formidable task, especially when the rhythm disturbances are infrequent and unexpected. An ILR device that can record events over a longer period of time may be the most effective way of making a diagnosis and of ultimately determining an appropriate treatment plan. The Reveal ILR can establish patient symptom/rhythm correlation during a spontaneous event, leading to a diagnosis of the underlying condition. Additionally, the device may reduce the need for repetitive low-yielding testing and decrease the time and costs associated with the diagnosis of unexplained recurrent syncope.[Abstract] [Full Text] [Related] [New Search]