These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Low-dose (1 microgram) adrenocorticotrophin (ACTH) stimulation as a screening test for impaired hypothalamo-pituitary-adrenal axis function: sensitivity, specificity and accuracy in comparison with the high-dose (250 microgram) test. Author: Tordjman K, Jaffe A, Trostanetsky Y, Greenman Y, Limor R, Stern N. Journal: Clin Endocrinol (Oxf); 2000 May; 52(5):633-40. PubMed ID: 10792344. Abstract: OBJECTIVE: We have shown previously that in contrast to the standard high-dose 250-microgram ACTH test, a low-dose 1-microgram ACTH stimulation test correctly identified all patients with pituitary disease who had impaired hypothalamo-pituitary-adrenal (HPA) function. In this study we further compared the performances of these two tests as screening procedures for possible HPA impairment. DESIGN: A comparison of the 1-microgram and the 250-microgram ACTH stimulation tests in healthy controls and in patients with pituitary disease whose HPA axis status was characterized formally by a gold standard test. SUBJECTS: A total of 89 subjects were investigated: 27 healthy normal controls, 43 patients with pituitary disease and normal HPA function, and 19 patients with various pituitary diseases and impaired HPA function. MEASURES: All 89 subjects underwent stimulation with 1 microgram ACTH; 80 also underwent the high-dose 250-microgram ACTH test. A receiver operating characteristic analysis (ROC) was performed to compare the tests. RESULTS: Using a stimulated cortisol > 500 nmol/l as the criterion for a normal response, the 1-microgram ACTH stimulation identified 18 of the 19 subjects with impaired HPA function (94.7% sensitivity with a likelihood ratio of 0.0588 for a negative test). In contrast, 15/16 passed the high-dose test (a 6.2% sensitivity with a likelihood ratio of 0.875 for a negative test). All normal controls, and 36/43 patients with preserved HPA function, passed the 1-microgram ACTH test (90% specificity). This degree of accuracy was unrivalled by the high dose test at all the cut-off levels considered. CONCLUSIONS: More sensitive and accurate, the low-dose 1-microgram ACTH test is as simple and safe as the standard 250-microgram test. We suggest it should replace it in screening for adrenal insufficiency.[Abstract] [Full Text] [Related] [New Search]