These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Methods for separation of contributions from two radionuclides in autoradiography with a silicon strip detector. Author: Kvinnsland Y, Skretting A. Journal: Phys Med Biol; 2000 May; 45(5):1183-93. PubMed ID: 10843099. Abstract: Two methods have been developed for the separation of contributions from two different nuclides in an autoradiography picture. Both approaches, a modified least squares (LS) and a maximum likelihood (ML) algorithm, are based on the position and energy information available from a digital detector. Tests and comparisons, using artificially as well as measured data, demonstrate that the ML approach performs slightly better, but is much more computationally demanding than the LS method.[Abstract] [Full Text] [Related] [New Search]