  • Title: [Non-surgical closure of patent ductus arteriosus: acute and long-term results].
    Author: Chatterjee T, Windecker S, Pfammatter JP, Seiler C, Meier B.
    Journal: Schweiz Med Wochenschr; 2000 May 06; 130(18):664-70. PubMed ID: 10846759.
    Abstract:
    INTRODUCTION: Closure of a patent ductus arteriosus (PDA) even with small shunt volumes in asymptomatic patients is recommended because of the risk of endocarditis (1.5% per year) and the potential development of congestive heart failure or pulmonary hypertension. METHODS: 16 patients (9 adults [5 men/4 women] and 7 children [3 boys/4 girls]) underwent transcatheter closure of a PDA. The intervention was performed using the Rashkind umbrella in 12 cases, the Amplatzer duct occluder in 2 cases, a coil in 2 cases, and the Sideris self-adjusting device in one case. Echocardiographic controls were carried out one day, 6 months, 12 months and 24 months after the intervention. RESULTS: PDA closure was complete immediately following the intervention in 9 of 16 patients (56%). At follow-up (mean 19 months) complete closure was observed in 14 of 16 patients (87%). All residual shunts were trivial. The complete closure rate in adults was 100% and in children 71%. Complications such as device embolism, endarteritis and haemolysis did not occur. CONCLUSION: Non-surgical closure of a PDA is a safe and effective technique.