These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Measurement of the force produced by an intact bull sperm flagellum in isometric arrest and estimation of the dynein stall force.
    Author: Schmitz KA, Holcomb-Wygle DL, Oberski DJ, Lindemann CB.
    Journal: Biophys J; 2000 Jul; 79(1):468-78. PubMed ID: 10866972.
    Abstract:
    The force generated by a detergent-extracted reactivated bull sperm flagellum during an isometric stall was measured with a force-calibrated glass microprobe. The average isometric stall force from 48 individual measurements was 2.5 +/- 0.7 x 10(-5) dyne (2.5 +/- 0.7 x 10(-10) N). The force measurements were obtained by positioning a calibrated microprobe in the beat path of sperm cells that were stuck by their heads to a glass microscope slide. The average position of the contact point of the flagellum with the probe was 15 microm from the head-tail junction. This average lever arm length multiplied by the measured force yields an estimate of the active bending moment (torque) of 3.9 x 10(-8) dyne x cm (3.9 x 10(-15) N x m). The force was sustained and was for the most part uniform, despite the fact that the flagellum beyond the point of contact with the probe usually continued beating. It appears that the dynein motors in the basal portion of the flagellum continue to pull in an isometric stall for as long as the motion of the flagellum is blocked. If dynein motors in the flagellum distal to the contact point with the probe were contributing force to the displacement of the probe, then the flagellar segment immediately past the point of contact would have to show a net curvature in the direction of the probe displacement. No such curvature bias was observed in the R-bend arrests, and only a small positive curvature bias was measured in the P-bend arrests. Our analysis of the data suggests that more than 90% of the sustained force component is generated by the part of the flagellum between the probe and the flagellar base. Based on this premise, the isometric stall force per dynein head is estimated to be 5.0 x 10(-7) dyne (5 pN). This equals approximately 1.0 x 10(-6) dyne (10 pN) per intact dynein arm. These values are close to the isometric stall force of isolated dynein. This suggests that all of the dynein heads between the base and the probe, on the active side of the axoneme, are contributing to the force exerted against the probe.
    [Abstract] [Full Text] [Related] [New Search]