These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Results of an uncemented straight femoral shaft prosthesis after 9 years of follow-up.
    Author: Eingartner C, Volkmann R, Winter E, Maurer F, Sauer G, Weller S, Weise K.
    Journal: J Arthroplasty; 2000 Jun; 15(4):440-7. PubMed ID: 10884203.
    Abstract:
    The first consecutive 250 implantations of an uncemented, proximally anchored straight femoral shaft prosthesis (BiCONTACT) in 236 patients are included in this prospective follow-up study. Average time of follow-up evaluation was 8.9 years (range, 7.4-10.7 years). At follow-up, 27 patients had died, and 2 could not be located. Seven patients underwent revision-2 for infection, 1 for recurrent dislocation, 2 for component undersizing with rapid subsidence, and 1 for aseptic loosening of a varus-malaligned stem; 1 radiologically well-fixed stem had been revised during acetabular revision. Overall survival was 97.1% after 11 years (confidence limits, 98.7% [upper] and 93.6% [lower]). The average Harris Hip score at time of follow-up was 84.3 points. Radiologically, tiny reactive lines (<2 mm) were present in the distal zones of the femoral shaft, but no radiolucencies could be found in the proximal anchoring zone. The midterm to long-term follow-up results with the evaluated femoral component are encouraging and are comparable to those of modern techniques of cementing in primary total hip arthroplasty.
    [Abstract] [Full Text] [Related] [New Search]