These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Detection of occult thymoma during exercise thallium 201, technetium 99m tetrofosmin imaging for coronary artery disease.
    Author: Paull DE, Graham J, Forgetta J, Turissini T, Saidman B.
    Journal: Chest; 2000 Aug; 118(2):550-1. PubMed ID: 10936156.
    Abstract:
    Thallium (Tl) 201 and technetium (Tc) 99m tetrofosmin single-photon emission CT are routinely used in the evaluation of coronary artery disease. Mediastinal tumors demonstrate Tl 201 and Tc 99m tetrofosmin uptake. We report a 56-year-old man who developed chest pain after a previously successful angioplasty and stent of the left anterior descending coronary artery. He underwent a Tl 201, Tc 99m tetrofosmin exercise study. Abnormal mediastinal activity was visualized in both the Tl 201 and Tc 99m tetrofosmin images. Subsequently, the patient underwent resection of a stage II thymoma. Unanticipated focal extracardiac accumulation during myocardial scintiscanning should lead to further investigation to exclude mediastinal tumor.
    [Abstract] [Full Text] [Related] [New Search]