These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Systemic assessment of fetal hemodynamics by Doppler ultrasound. Author: Chang CH, Chang FM, Yu CH, Liang RI, Ko HC, Chen HY. Journal: Ultrasound Med Biol; 2000 Jun; 26(5):777-85. PubMed ID: 10942825. Abstract: The aim of our study was to investigate the parameters of fetal circulation of normal pregnancies and their relationship to fetal cardiac output. We performed a cross-sectional study of 315 normal singleton pregnancies between 20 and 40 weeks' gestation without fetal chromosomal or structural malformations. After follow-up to delivery, 212 patients who fit all the criteria were enrolled for final analysis. Blood flow velocity waveforms were obtained from the tricuspid and mitral ventricular inflow, ascending aorta (AAO), pulmonary artery (PA), middle cerebral artery (MCA), renal artery (RA), umbilical artery (UA), descending aorta (DAO), inferior vena cava (IVC) and ductus venosus (DV) using duplex (real-time Doppler) ultrasound (US) scanner. The peak velocity of DV, AAO, PA and MCA were also obtained. At the intracardiac level, the ratio of peak flow velocity of E wave to peak flow velocity of A wave (E:A ratio) of mitral valve (MV) increased more rapidly than tricuspid valve (TV) E:A ratio. For the great vessels, aortic peak velocity remained higher than the pulmonary peak velocity with advancing gestation. The cardiac output closely correlated to the cardiac compliance and flow resistance indices at arterial and venous level. The acceleration time in the fetal arteries increased with advancing gestation in AAO, PA, MCA and DAO, but it decreased in RA and kept constant in UA. In addition, the acceleration time of UA was unrelated to cardiac output. The changes of the fetal intracardiac, arterial and venous impedances were remarkable through the gestation and related to cardiac output. Fetal cardiac output correlated well with the changes of arterial resistance, except with the DAO. The ventricular compliance increased with advancing gestation, especially in the left side, and was highly related to the change of cardiac output. The acceleration time in major arteries positively correlated with the gestational age and cardiac output, except in UA and RA; this indicates the difference of the changes of mean arterial pressure in uteroplacental circulation, fetal organs and great vessels. In conclusion, the fetal cardiac output correlated well with the ventricular compliance and was influenced by both hemodynamic changes in peripheral resistance and mean arterial pressure.[Abstract] [Full Text] [Related] [New Search]