These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: The optic nerve head as a biomechanical structure: initial finite element modeling.
    Author: Bellezza AJ, Hart RT, Burgoyne CF.
    Journal: Invest Ophthalmol Vis Sci; 2000 Sep; 41(10):2991-3000. PubMed ID: 10967056.
    Abstract:
    PURPOSE: To study the relationship between intraocular pressure (IOP) and the IOP-related stress (force/cross-sectional area) it generates within the load-bearing connective tissues of the optic nerve head. METHODS: Thirteen digital, three-dimensional geometries were created representing the posterior scleral shell of 13 idealized human eyes. Each three-dimensional geometry was then discretized into a finite element model consisting of 900 constituent finite elements. In five models, the scleral canal was circular (diameters of 0.50, 1.50, 1.75, 2.00, and 2.56 mm), with scleral wall thickness (0.8 mm) and inner radius (12.0 mm) held constant. In three models, the canal was elliptical (vertical-to-horizontal ratios of 2:1 [2.50 x 1.25 mm], 1.5:1 [2.1 x 1.4 mm], and 1.15:1 [1.92 x 1.67 mm]), with the same constant scleral wall thickness and inner radius. In five additional models, scleral canal size was held constant (1.92 x 1.67 mm), and either scleral wall thickness (three models, 0.5, 1.0, and 1.5 mm) or inner radius (two models, 13.0 and 14.0 mm) was varied. In all models, each finite element was assigned a single isotropic material property, either scleral (modulus of elasticity, 5500 kPa) or axonal (modulus of elasticity, 55 kPa). Maximum stresses within specific regions were calculated at an IOP of 15 mm Hg (2000 Pa). RESULTS: Larger scleral canal diameter, elongation of the canal, and thinning of the sclera increased IOP-related stress for a given level of IOP. For all models, maximum IOP-related stress ranged from 6 x IOP (posterior sclera) to 122 x IOP (laminar trabeculae). For each model, maximum IOP-related stress was highest within the laminar trabecular region and decreased progressively through the laminar insertion, peripapillary scleral, and posterior scleral regions. Varying the inner radius had little effect on the maximum IOP-related stress within the scleral canal. CONCLUSIONS: Initial finite element models show that IOP-related stress within the load-bearing connective tissues of the optic nerve head is substantial even at low levels of IOP. Although the data suggest that scleral canal size and shape and scleral thickness are principal determinants of the magnitude of IOP-related stress within the optic nerve head, models that incorporate physiologic scleral canal and laminar geometries, a more refined finite element model meshwork, and nonisotropic material properties will be required to confirm these results.
    [Abstract] [Full Text] [Related] [New Search]