These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Partial upper re-sternotomy for aortic valve replacement or re-replacement after previous cardiac surgery.
    Author: Byrne JG, Karavas AN, Adams DH, Aklog L, Aranki SF, Couper GS, Rizzo RJ, Cohn LH.
    Journal: Eur J Cardiothorac Surg; 2000 Sep; 18(3):282-6. PubMed ID: 10973536.
    Abstract:
    OBJECTIVE: We developed techniques for 'inverted T' partial upper re-sternotomy for aortic valve replacement (AVR) or re-replacement (AVreR) after previous cardiac surgery. We previously reported on decreased blood loss, transfusion requirements and total operative duration when compared to conventional full re-sternotomy. This report updates our series, one of the few to document a substantial benefit from a 'minimally-invasive' approach, refines a number of technical aspects of this new approach and reports follow-up. METHODS: Between November 1996 and December 1999, we performed 34 AVRs or AVreRs after previous cardiac surgery by use of an 'inverted T' partial upper re-sternotomy. There were 25 (74%) men. Median ejection fraction was 54%, range 15-80%. Median age was 72, range 38-93. All were New York Heart Association functional class (NYHA) functional class II or III. Twenty-one (62%) had previous coronary artery bypass grafts (CABG) while 14 (41%) had previous valve surgery. Follow-up was 100% complete for a total of 593 patient months (median 19 months). RESULTS: Twenty-three (66%) underwent AVR of the native aortic valve while 11 (33%) underwent AVreR of a prosthetic aortic valve. There were no intraoperative or valve-related complications, and no conversion to full re-sternotomy was necessary. There were two (5.9%) operative deaths from an arrhythmia on postoperative day 4 and a large stroke during surgery, respectively. Twenty-four (75%) patients were free of major complications. There was no need for reoperation for bleeding and patients required a median of two units of packed red blood cells. Complications included new atrial fibrillation (n=3, 9%), pacemaker implantation (n=3, 9%) and deep sternal wound infection (n=2, 6%). Median lengths of stay in the intensive care unit (ICU) and in the hospital were 1 and 7 days, respectively. There was one (3%) late deep sternal wound infection and 2/32 (6%) late deaths due to congestive heart failure at 22 months and myocardial infarction at 23 months, respectively. CONCLUSIONS: Partial upper re-sternotomy presents a safe and effective alternative approach to AVR and AVreR after previous cardiac surgery, and is associated with low morbidity and mortality.
    [Abstract] [Full Text] [Related] [New Search]