These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Evaluation of a new method of small fragment fixation in a medial malleolus fracture model.
    Author: Rovinsky D, Haskell A, Liu Q, Paiement GD, Robinovitch S.
    Journal: J Orthop Trauma; 2000 Aug; 14(6):420-5. PubMed ID: 11001416.
    Abstract:
    OBJECTIVE: To evaluate a new method of small fragment fixation in a medial malleolus fracture model. DESIGN/METHODS: The authors measured the pullout strength, resistance to shear stress, and speed of insertion of 4.0-millimeter partially threaded cancellous screws, 2.4-millimeter smooth K-wires, and a small fragment fixation system with 2.2-millimeter threaded K-wires. Pullout strength was tested in eighty-one synthetic foam blocks and resistance to shear stress in thirty synthetic tibias by use of a servohydraulic testing machine. Six randomized time trials with the threaded K-wires and cancellous screws were also conducted. RESULTS: Pullout strength increased with increasing foam density, increasing insertion depth, and varied with fixation method (p < 0.05). Maximum pullout strengths were as follows: partially threaded cancellous screws, 730+/-4 Newtons; threaded K-wires, 316+/-12 Newtons; and smooth K-wires, 172 +/-5 Newtons. Percent difference in pullout strength between the partially threaded cancellous screw and threaded K-wire diminished with increased depth of insertion and increased foam density. Offset axial load to initiate fracture displacement in a synthetic tibia model averaged 1540+/-138 Newtons for the partially threaded cancellous screws, 1,318+/-117 Newtons for the threaded K-wires, and 1,287+/-121 Newtons for the smooth K-wires (p > 0.05). Average time of fixation of a medial malleolar fragment by orthopedic surgeons with a variety of experience levels in a synthetic tibia with two threaded K-wires (114+/-8 seconds) was significantly faster (p < 0.05) than with two partially threaded cancellous screws (207+/-20 seconds). CONCLUSIONS: Threaded K-wires show substantial pullout strength and similar resistance to offset axial load when compared with partially threaded cancellous screws. These threaded K-wires offer an alternative for the internal fixation of medial malleolus fractures.
    [Abstract] [Full Text] [Related] [New Search]