These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Conventional running suture and continuous double loop closure: an experimental study of wound strength. Author: Cengiz Y, Månsson P, Israelsson LA. Journal: Eur J Surg; 2000 Aug; 166(8):647-9. PubMed ID: 11003435. Abstract: OBJECTIVE: To study the strength of laparotomy wounds closed by a continuous double loop technique or a conventional running suture, taking into account the ratio of suture length: wound length. DESIGN: Experimental study. ANIMALS: 60 Sprague-Dawley rats. INTERVENTIONS: Midline laparotomy incisions were closed with either a conventional running suture or a continuous double loop. Wounds were allocated to closure with a suture length: wound length ratio of 3, 4 and 7. MAIN OUTCOME MEASURES: Bursting pressure, bursting volume and the way the suture cut through the tissues. RESULTS: With a suture length: wound length ratio of 3 or 4 bursting pressure and bursting volume were lower with a continuous double loop closure. A conventional running suture and a continuous double loop produced similar bursting pressure and bursting volume only if closure was with a ratio of 7. CONCLUSIONS: Wound bursting strength is higher with a conventional running suture than with a continuous double loop closure when the effect of the suture length: wound length ratio is accounted for.[Abstract] [Full Text] [Related] [New Search]