These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: The need for chromatographic and mass resolution in liquid chromatography/tandem mass spectrometric methods used for quantitation of lactones and corresponding hydroxy acids in biological samples. Author: Jemal M, Ouyang Z. Journal: Rapid Commun Mass Spectrom; 2000; 14(19):1757-65. PubMed ID: 11006583. Abstract: Because of the potential in-source conversion between a lactone and the corresponding hydroxy acid, it has been recognized that a liquid chromatography/tandem mass spectrometric (LC/MS/MS) method developed for quantitation of a lactone drug in the presence of its hydroxy acid metabolite (or vice versa) must incorporate chromatographic separation between the two compounds, unless in-source conversion between the two compounds has been eliminated by the appropriate selection of the LC/MS/MS parameters. We now report that chromatographic separation between a lactone and its hydroxy acid will be required under certain LC/MS/MS conditions used even in the absence of in-source conversion. This is due to the fact that the 18-mass-unit difference between a lactone and its hydroxy acid is, by coincidence, different by only one mass unit from the 17-mass-unit difference between the [M + H](+) and [M + NH(4)](+) ions of the lactone or the hydroxy acid. Thus, the [M + H](+) ion of a hydroxy acid is higher than the [M + NH(4)](+) ion of its lactone by only one mass unit. Therefore, in a method developed for quantitation of a hydroxy acid drug utilizing a selected-ion-monitoring (SRM) scheme that incorporates its [M + H](+) ion as the precursor ion, the quantitation would be inaccurate due to the interference by the contribution of the A + 1 isotope response from the [M + NH(4)](+) ion of the lactone metabolite present in the sample, unless there is a chromatographic separation between the two compounds. This is true even if Q1 is operated under a unit-mass resolution. The implication of this type of interference, arising from the presence of both the [M + H](+) and [M + NH(4)](+) ions of a drug and its metabolite, to the selection of LC and MS conditions (including mass resolution) will be discussed using the data obtained with a model lactone drug and its hydroxy acid metabolite.[Abstract] [Full Text] [Related] [New Search]