These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Use of a new monoclonal antibody-based enzyme immunoassay for soluble fibrin to exclude pulmonary embolism. ANTELOPE-Study Group. Author: Mac Gillavry MR, Sanson BJ, de Monyé W, Lijmer JG, Huisman MV, Büller HR, Nieuwenhuizen W, Brandjes DP. Journal: Thromb Haemost; 2000 Sep; 84(3):474-7. PubMed ID: 11019974. Abstract: We prospectively evaluated the diagnostic performance of a new soluble fibrin assay in 303 consecutive patients with suspected pulmonary embolism and examined potentially useful cut-off levels at which this disease can be safely excluded. In addition, the diagnostic accuracy was calculated in the subgroups of in- and outpatients. The ROC curve of the assay in the total study cohort had an area under the curve of 0.69. The cut-off level associated with a sensitivity and negative predictive value of 100% was 20 ng/ml, but the specificity was only 4%. The cut-off level with a sensitivity of 90% was 30 ng/ml, which corresponded with a specificity and negative predictive value of 27% and 86%. respectively. The diagnostic performance was comparable in the subgroups of in- and outpatients. We conclude that the soluble fibrin assay has a low diagnostic accuracy and seems unsuitable as a screening test for the exclusion of pulmonary embolism.[Abstract] [Full Text] [Related] [New Search]