These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Serum cystatin C as an endogenous parameter of the renal function in patients with normal to moderately impaired kidney function. Author: Randers E, Erlandsen EJ, Pedersen OL, Hasling C, Danielsen H. Journal: Clin Nephrol; 2000 Sep; 54(3):203-9. PubMed ID: 11020018. Abstract: BACKGROUND: Cystatin C is a proteinase inhibitor with a low molecular weight. The serum levels of cystatin C are mainly dependent on glomerular filtration rate (GFR) making cystatin C an endogenous parameter of GFR. The aim of the study was to elucidate the applicability of serum cystatin C as a parameter of GFR in patients with normal to moderately impaired kidney function and to estimate a reference interval for serum cystatin C. PATIENTS AND METHODS: Forty-six patients (25 males and 21 females) aged 22 to 83 years with various kidney diseases and 250 blood donors (164 males and 86 females) aged 19 to 64 years were included. Cystatin C was measured by an automated particle-enhanced nephelometric immunoassay, serum creatinine by an enzymatic and by Jaffé method, urine creatinine by an enzymatic method, and GFR by 99mTc-DTPA clearance. RESULTS: Serum levels ofcystatin C and creatinine showed increments with decreasing values of 99mTc-DTPA clearance and a linear relationship was found between 99mTc-DTPA clearance and l/serum cystatin C, l/serum creatinine (enzymatic method), and creatinine clearance. Comparison of the non-parametric receiver-operating characteristic (ROC) plots for serum cystatin C (area under the curve (AUC) = 0.996; SE = 0.005), serum creatinine (enzymatic method) (AUC = 0.899; SE = 0.044), serum creatinine (Jaffé method) (AUC = 0.870; SE = 0.051), measured creatinine clearance (AUC = 0.959; SE = 0.025), and estimated creatinine clearance (0.950; SE = 0.029) revealed significant differences for serum cystatin C and serum creatinine (enzymatic and Jaffé method) (p values: 0.03 and 0.01). No significant differences were demonstrated between serum cystatin C and measured and estimated creatinine clearance (p value: 0.14 and 0.12). The non-parametric reference interval for serum cystatin C was calculated to be 0.51-1.02 mg/l (median: 0.79 mg/l; range: 0.33 - 1.07 mg/l). CONCLUSION: Serum cystatin C seems to be a better parameter of GFR than serum creatinine in adults with various types of kidney disease with normal to moderately impaired kidney function.[Abstract] [Full Text] [Related] [New Search]