These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Basket catheter-guided three-dimensional activation patterns construction and ablation of common type atrial flutter.
    Author: Zrenner B, Ndrepepa G, Schneider M, Karch M, Deisenhofer I, Schreieck J, Schömig A, Schmitt C.
    Journal: Pacing Clin Electrophysiol; 2000 Sep; 23(9):1350-8. PubMed ID: 11025890.
    Abstract:
    Construction of three-dimensional activation maps and evaluation of ablation-created bidirectional block in the tricuspid valve-inferior vena caval (TV-IVC) isthmus in patients with atrial flutter (AF) are difficult with conventional mapping technique. In 36 patients with type I AF (25 men, 11 women; mean age 62 +/- 10.5 years) a multielectrode basket catheter (BC) was deployed in the right atrium (RA). Out of 64 BC electrodes, 56 bipolar electrograms were derived. Three-dimensional activation patterns were constructed with a software program. Stable electrograms of satisfactory quality were obtained in 49 +/- 2 electrode pairs. Capture was possible in 36 +/- 3 of bipoles. In counterclockwise AF (CCW-AF) and clockwise AF (CW-AF) episodes, cycle lengths and TV-IVC isthmus conduction times were 248 +/- 26 ms and 251 +/- 23 ms, (P = 0.74) and 105 +/- 28 ms and 106 +/- 33 ms (P = 0.92), respectively. Conduction velocity in the TV-IVC isthmus was lower than in the anterior or septal limbs of the circuit, in counterclockwise or clockwise episodes. Double potentials were recorded in 94% of patients. Three-dimensional activation patterns were delineated and displayed as isochronal maps. The reentry circuit involved the TV-IVC isthmus, septal, and anterior walls and a part of the RA roof anterior to superior vena cava. Postablation isthmus conduction was evaluated through the sequence criteria, local electrogram-based criteria, and the analysis of three-dimensional activation patterns of the paced rhythms. The complete isthmus block was associated with a significant increase of the low anterior low septal conduction interval (152 +/- 29 vs 104 +/- 32 ms, P = 0.001) and the low septal-low anterior conduction interval (150 +/- 31 vs 107 +/- 33 ms, P = 0.001). Radiofrequency ablation was successful in 32 (90%) of 36 patients. In conclusion, the current mapping system enables construction of three-dimensional activation patterns and facilitates evaluation of the postablation TV-IVC isthmus block in patients with AF.
    [Abstract] [Full Text] [Related] [New Search]