These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Alterations in the fibrinolytic system components during acute myocardial infarction. Author: Ioannidou-Papayannaki E, Lefkos N, Boudonas G, Efthimiadis A, Psirropoulos D, Vogas V, Papadopoulos I, Klonizakis I. Journal: Acta Cardiol; 2000 Aug; 55(4):247-53. PubMed ID: 11041123. Abstract: The purpose of this study was to evaluate the changes in tissue-plasminogen activator (t-PA), plasminogen activator inhibitor - type 1 (PAI-1) and D-dimer (DD) antigen plasma levels in acute myocardial infarction (AMI) patients after thrombolytic therapy with two different thrombolytic agents, rt-PA or acetyl-streptokinase and to find out any correlation between the plasma t-PA, PAI-1 and DD levels with the infarct size as it is estimated from the peak of serum CPK levels. The plasma antigen levels of t-PA, PAI-1 and DD were measured by the enzyme immunoassay method (Stago), in 57 consecutive patients (M = 46, F = 11, mean age 55.6 +/- 8.8 years) and in 25 normal subjects (M = 18, F = 7, mean age 54.0 +/- 5.5 years). In 47 out of the 57 patients who were treated successfully with 100 mg of rt-PA (26 patients) or with 1.5 MU 21 of acetyl-streptokinase, as well as in 10 patients who were not treated, samples were obtained again 4 and 24 hours after the end of thrombolytic therapy or admission, respectively. During the acute phase of myocardial infarction the t-PA, PAI-1 and DD antigen plasma levels were significantly higher than in healthy people. There were no significant changes in the t-PA, PAI-1 and DD plasma levels of the patients who were not treated with a thrombolytic agent. We found a significant elevation of t-PA (p < 0.001), PAI-1 (p < 0.05) and DD (p < 0.001) after 4 hours in comparison with the baseline (at presentation, before therapy). After 24 hours the t-PA and DD plasma levels remained significantly higher (p < 0.001) while the PAI-1 plasma levels returned to the pre-therapy levels. There were no significantly different changes in the t-PA, PAI-1 and DD plasma levels of either group of patients, treated with rt-PA or acetyl-streptokinase while the t-PA and PAI-1 levels were positively correlated with infarct size as estimated from peak serum CPK levels.[Abstract] [Full Text] [Related] [New Search]