These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Bioavailability and pharmacokinetic profile of glyceryl trinitrate and of glyceryl dinitrates during application of a new glyceryl trinitrate transdermal patch. Author: Santoro A, Rovati LC, Setnikar I, Caplain H, Gualano V. Journal: Arzneimittelforschung; 2000 Sep; 50(9):779-85. PubMed ID: 11050693. Abstract: The pharmacokinetics and bioavailability of glyceryl trinitrate (GTN, CAS 55-63-0) and of its main metabolites, i.e. 1,2-glyceryl dinitrate (1,2-GDN, CAS 621-65-8) and 1,3-glyceryl dinitrate (1,3-GDN, CAS 623-87-0), were compared during a single 24-h application of a new GTN transdermal patch (Epinitril 10, hereinafter called EPI-10) or a reference patch (hereinafter called ND-10) releasing 10 mg GTN in 24 h. The study was an open, randomized balanced cross-over study on 24 healthy male volunteers to whom the patches were applied to the antero-lateral part of the thorax in two periods separated by a 3-day wash-out. Blood samples were collected before administration, during the 24-h patch application and at 0.5, 2 and 3 h after patch removal. Assayed in plasma were GTN, 1,2-GDN and 1,3-GDN using validated GC/MS methods with stable isotope-labeled internal standards (15N3-GTN, 15N2-1,2-GDN, and 15N2-1,3-GDN). The ratios of the AUCs of GTN, 1,2-GDN and 1,3-GDN measured during application of EPI-10 or of ND-10 were within the 0.85-1.25 limits required to assess equivalence of the extent of bioavailability. The ratios of the Cmax were within said limits for the signal metabolite 1,2-GDN and only slightly below (0.78-1.16) for the parent GTN. EPI-10 can therefore be considered equivalent to ND-10 also with regard to the rate of bioavailability. Under both patches GTN reached steady-state levels after 3-6 h of patch application and remained on sustained levels during the whole 24-h application. The plasma levels of 1,2-GDN were about 6 times higher than those of GTN. The plasma levels of 1,3-GDN were similar to those of GTN. Upon removal of the patches the concentrations of the three nitrates fell to negligible values within 3 h. Both patches were well tolerated at the application site. For its small size, thinness and transparency, EPI-10 is very patient friendly, a quality that improves compliance with the therapeutic regimen.[Abstract] [Full Text] [Related] [New Search]