These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Measurement of reticulated platelet using whole blood: methodology and clinical application].
    Author: Nishiyama M, Hayashi S, Futsukaichi Y, Suehisa E, Kurata Y.
    Journal: Rinsho Byori; 2000 Sep; 48(9):872-6. PubMed ID: 11051807.
    Abstract:
    We established simple and rapid method to measure reticulated platelets using whole blood. After whole blood was fixed with paraformaldehyde, sample was stained with thiazole orange and analyzed using flow cytometer. %RP was significantly higher in patients with idiopathic thrombocytopenic purpura(ITP) (27.7 +/- 14.3%) compared with that of normal subjects(11.9 +/- 3.1%), and elevated in 73% of ITP patients. Furthermore, %RP reflected the status of disease very well in a patient with ITP undergoing therapy. Our method can be effectively applied for differential diagnosis and assessment of the status of thrombocytopenic disorders.
    [Abstract] [Full Text] [Related] [New Search]