These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: A decade of postlaryngectomy vocal rehabilitation in 318 patients: a single Institution's experience with consistent application of provox indwelling voice prostheses. Author: Op de Coul BM, Hilgers FJ, Balm AJ, Tan IB, van den Hoogen FJ, van Tinteren H. Journal: Arch Otolaryngol Head Neck Surg; 2000 Nov; 126(11):1320-8. PubMed ID: 11074828. Abstract: OBJECTIVE: To assess long-term results with consistent use of indwelling voice prostheses (Provox; Atos Medical AB, Hörby, Sweden) for vocal rehabilitation after total laryngectomy. DESIGN: Retrospective clinical analysis. SETTING: Comprehensive national cancer center. PATIENTS: Three hundred eighteen patients (261 men and 57 women; mean age, 62 years) from November 1988, through May 1999. INTERVENTION: Standard wide-field total laryngectomy (287 patients) or total laryngectomy with circumferential pharyngeal resection (31 patients), and 2700 prosthesis replacements. Prostheses remained in situ during 364,339 days (1000 patient-years). MAIN OUTCOME MEASURES: Device lifetime, indications for replacement (device or fistula related), adverse events, and voice quality. RESULTS: Median patient-device follow-up was 67 months. Mean actuarial device lifetime for all indications for replacement was 163 days (median, 89 days). Main indications for replacement were device-related, ie, leakage through the prosthesis (73%) and obstruction (4%), or fistula-related, ie, leakage around the prosthesis (13%), and hypertrophy and/or infection of the fistula (7%). Adverse events occurred in 11% of all replacements in one third of the patients, mostly solvable by a shrinkage period, or adequate sizing and/or antibiotic treatment. Definitive closure of the tracheoesophageal fistula tract occurred in 5% of the patients. Significant clinical factors for increased device lifetime were no radiotherapy (P =.03), and age older than 70 years (P<.02). Success rate with respect to voice quality (ie, fair to excellent rating) was 88%, which was significantly influenced by the extent of surgery (P<.001). CONCLUSION: The consistent use of indwelling voice prostheses shows a high success rate of prosthetic vocal rehabilitation, in terms of the percentage of long-term users (95%), and of a fair-to-excellent voice quality (88% of patients).[Abstract] [Full Text] [Related] [New Search]