  • Title: Outbreak of severe Pseudomonas aeruginosa infections caused by a contaminated drain in a whirlpool bathtub.
    Author: Berrouane YF, McNutt LA, Buschelman BJ, Rhomberg PR, Sanford MD, Hollis RJ, Pfaller MA, Herwaldt LA.
    Journal: Clin Infect Dis; 2000 Dec; 31(6):1331-7. PubMed ID: 11095998.
    Abstract:
    During a 14-month period, 7 patients with hematological malignancies acquired serious infections caused by a single strain of multiply resistant Pseudomonas aeruginosa. A case-control study, culture surveys, and pulsed-field gel electrophoresis implicated a whirlpool bathtub on the unit as the reservoir. All case patients and 32% of control patients used this bathtub (P=.003). The epidemic strain was found only in cultures of samples taken from the bathtub. The drain of the whirlpool bathtub, which was contaminated with the epidemic strain, closed approximately 2.54 cm below the drain's strainer. Water from the faucet, which was not contaminated, became contaminated with P. aeruginosa from the drain when the tub was filled. The design of the drain allowed the epidemic strain to be transmitted to immunocompromised patients who used the whirlpool bathtub. Such tubs are used in many hospitals, and they may be an unrecognized source of nosocomial infections. This potential source of infection could be eliminated by using whirlpool bathtubs with drains that seal at the top.