These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Determination of the designer drugs 3, 4-methylenedioxymethamphetamine, 3,4-methylenedioxyethylamphetamine, and 3,4-methylenedioxyamphetamine with HPLC and fluorescence detection in whole blood, serum, vitreous humor, and urine. Author: Clauwaert KM, Van Bocxlaer JF, De Letter EA, Van Calenbergh S, Lambert WE, De Leenheer AP. Journal: Clin Chem; 2000 Dec; 46(12):1968-77. PubMed ID: 11106329. Abstract: BACKGROUND: The popular designer drugs 3, 4-methylenedioxymethamphetamine (MDMA) and 3, 4-methylenedioxyethylamphetamine (MDEA) can be determined in serum, whole blood, and urine, but also in vitreous humor. The latter matrix is interesting when dealing with decomposed bodies in a toxicological setting. METHODS: After extraction, chromatographic separation was achieved on a narrow-bore C(18) column by gradient elution with fluorometric detection; results were confirmed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). RESULTS: The method was linear over the range of 2-1000 microg/L for whole blood, serum, and vitreous humor, and 0.1-5 mg/L for urine. Extraction recoveries were >70%, imprecision (CV) was 2.5-19%, and analytical recoveries were 95.5-104.4%. The limit of detection (LOD) and the limit of quantification (LOQ) were 0.8 and 2 microg/L, respectively, for whole blood, serum, and vitreous humor, and 2.5 microg/L and 0.1 mg/L, respectively, for urine. Excellent correlations between the quantitative LC-fluorescence and LC-MS/MS results were obtained. We found the following concentrations in a thanatochemical distribution study in rabbits: in serum, 5.3-685 microg/L for MDMA and from the LOQ to 14.5 microg/L for 3, 4-methylenedioxyamphetamine (MDA); in whole blood, 19.7-710 microg/L for MDMA and from the LOQ to 17.8 microg/L for MDA; in vitreous humor, 12.1-97.8 microg/L for MDMA and from the LOQ to 3.86 microg/L for MDA. In routine toxicological urine samples, concentrations ranged from LOQ to 14.62 mg/L for MDA, from LOQ to 157 mg/L for MDMA, and from LOQ to 32.54 mg/L for MDEA. CONCLUSIONS: The HPLC method described is sensitive, specific, and suitable for the determination of MDMA, MDEA, and MDA in whole blood, serum, vitreous humor, and urine.[Abstract] [Full Text] [Related] [New Search]