These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: The role of central corneal thickness in the diagnosis of glaucoma.
    Author: Thomas R, Korah S, Muliyil J.
    Journal: Indian J Ophthalmol; 2000 Jun; 48(2):107-11. PubMed ID: 11116505.
    Abstract:
    PURPOSE: To determine the effect of central corneal thickness (CCT) on applanation tonometry and any resultant misclassification of normals as ocular hypertension. METHOD: The central corneal thickness was measured using the ultrasound pachometer in 50 normals, 25 glaucoma and 23 ocular hypertensive patients. The student's "t" test was used to determine any significant difference in CCT between the three groups. RESULTS: There was a statistically significant difference in the mean CCT of the ocular hypertensives (0.574 +/- 0.033 mm) as compared to the glaucomas (0.534 +/- 0.030 mm) and normals (0.537 +/- 0.034 mm). Applying the described correction factor for corneal thickness, 39% of eyes with ocular hypertension were found to have a corrected IOP of 21 mmHg or less. CONCLUSIONS: Increased corneal thickness in ocular hypertension may lead to an overestimation of IOP in 39% of cases. Measurement of central corneal thickness is advisable when the clinical findings do not correlate with the applanation IOP.
    [Abstract] [Full Text] [Related] [New Search]