These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Semi-automated direct epifluorescent filter technique for total bacterial count in raw milk.
    Author: Hermida M, Taboada M, Menéndez S, Rodríguez-Otero JL.
    Journal: J AOAC Int; 2000; 83(6):1345-8. PubMed ID: 11128136.
    Abstract:
    The Direct Epifluorescent Filter Technique (DEFT) and the reference method of counting total bacterial colonies on Petri dishes were compared. IDF Standards 128 (1985) and 161A (1995) were applied. A total of 496 samples of milk were analyzed. Colony forming units per microL milk were transformed to decimal logarithmic units: log (cfu/microL). The repeatability standard deviation, Sr = 0.114, was typical for a routine microbiological method. To study the carryover at different levels of bacteria, 3 tests were performed on milk samples of approximately 100, 700, and >1000 cfu/microL. For the first 2 experiments, no carryover was detected; in the milk sample with >1000 cfu/microL, the carryover was <0.12%. When the DEFT counts were regressed versus the reference method, the values of the slope and intercept were 0.92 and 0.17, respectively; the correlation coefficient was r = 0.84; and the residual standard deviation was Syx = 0.287. The paired t-test showed that the reference method and DEFT do not give significantly different results (p = 0.05).
    [Abstract] [Full Text] [Related] [New Search]