These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: An assessment of intraocular pressure rise in patients with gas-filled eyes during simulated air flight.
    Author: Mills MD, Devenyi RG, Lam WC, Berger AR, Beijer CD, Lam SR.
    Journal: Ophthalmology; 2001 Jan; 108(1):40-4. PubMed ID: 11150262.
    Abstract:
    PURPOSE: To investigate the safety of aircraft flight for patients with small volumes of residual postoperative intraocular gas. DESIGN: Nonrandomized comparative trial. PARTICIPANTS: Seventeen eyes (nine gas filled and eight control eyes) of nine patients and one eye of one control subject were tested. METHODS: Patients with postoperative intraocular gas and the control subject were tested in the controlled environment of a hypobaric chamber to simulate the cabin depressurization associated with a typical commercial aircraft flight. Before, during, and after a simulated flight, the intraocular pressure (IOP) in the gas-containing and contralateral eyes was tested using the Perkins (Edinburgh, UK) and Tono-Pen XL (Jacksonville, FL) tonometers. MAIN OUTCOME MEASURES: The absolute and percentage change in IOP with varied cabin pressurization. RESULTS: Of the nine patients with intraocular gas, seven had 10% to 15% gas volume and two had 20% gas volume. In the 10% to 15% gas volume group, the IOP rose by an average of 109% from baseline during ascent to an average cabin altitude of 7429 feet above sea level. The IOP dropped to an average of 30% above baseline IOP during the cruise phase and further decreased to an average of 38% below baseline IOP on return to baseline altitude. In the 20% gas volume group, the IOP rose by an average of 84% from baseline during ascent to an average cabin altitude of 3400 feet above sea level. The IOP dropped to an average of 42% below baseline IOP on return to baseline altitude. The IOP in the contralateral control eyes did not vary with altitude changes. No patient experienced pain or visual loss during the experiments. CONCLUSIONS: Our results demonstrate that IOP may rise significantly in gas-filled eyes during simulated air flight, supporting the current conservative recommendation against air travel for most patients with intraocular gas bubbles. Further testing is warranted to develop a more objective measure of intraocular gas volume estimation and to define better the tolerability of aircraft flight for patients with intraocular gas.
    [Abstract] [Full Text] [Related] [New Search]