These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Immunoassays for the quantitation of porcine PAI-1 antigen and activity in biological fluid samples. Author: Leng HM, Brouwers E, Knockaert I, Declerck PJ. Journal: Thromb Haemost; 2000 Dec; 84(6):1082-6. PubMed ID: 11154117. Abstract: Two monoclonal antibody-based enzyme-linked immunosorbent assays (ELISAs) for the quantitation of porcine plasminogen activator inhibitor-1 (PAI-1) antigen and activity in plasma were constructed and validated. The intra-assay, interassay, and interdilution coefficients of variation were 4.3, 13, and 8%, respectively, for the antigen ELISA and 5, 16, and 11% for the activity assay. Assay recoveries, in the antigen ELISA. of either latent or active recombinant porcine PAI-1 (10 and 50 ng/ml) added to plasma were 86 +/- 9% and 92 +/- 22%, respectively, for the latent form and 89 +/- 99% and 87 +/- 7% for the active form (mean +/- SD, n = 3 to 4). In the immunofunctional assay, recoveries for the same concentrations of active PAI-1 were 108 +/- 16% and 92 +/- 21%, respectively. In male porcine plasma the level of PAI-1 antigen was 31 +/- 11 ng/ ml and the activity, 34 +/- 16 ng/ml (mean +/- SD, n = 10). In female plasma PAI-1 antigen levels were 20 +/- 5.2 ng/ml and the PAI-1 activity 42 +/- 17 ng/ml (n = 13). A linear correlation was found between PAI-1 antigen and activity levels in male (r = 0.60) and female (r = 0.70) plasma. Immunodepletion resulted in a decrease of >95% of the original PAI-1 antigen or activity levels. Incubation of plasma samples at 37 degrees C for 16 h resulted in a significant decrease (70 to 85%) of PAI-1 activity. Under these conditions (37 degrees C, 16 h) PAI-1 antigen levels remained unchanged in males whereas the response of the female samples in the PAI-1 antigen assay increased two-fold. In lysed platelet-rich plasma males had 990 +/- 470 ng/ml antigen and 160 +/- 80 ng/ml activity and females, 920 +/- 500 ng/ml antigen and 150 +/- 98 ng/ml activity corresponding to 2.1 +/- 0.77 fg PAI-1 antigen per platelet. Only 16% of PAI-1 released from platelets was found to be active. Linear correlations between PAI-1 antigen and activity were found for both males (r = 0.61) and females (r = 0.67). The assays are both sensitive and specific and may, therefore, aid the elucidation of the pathophysiological role of PAI-1 in swine experimental models of atherosclerosis and other thrombotic disorders.[Abstract] [Full Text] [Related] [New Search]