These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Factors affecting the efficiency of aerosol therapy with pressurised metered-dose inhalers through plastic spacers.
    Author: Chuffart AA, Sennhauser FH, Wildhaber JH, Swiss Paediatric Respiratory Physiology Research Group.
    Journal: Swiss Med Wkly; 2001 Jan 12; 131(1-2):14-8. PubMed ID: 11205181.
    Abstract:
    AIM: The main objective of this study was to compare the in vitro delivery of salbutamol from a chlorofluorocarbon(CFC)-propelled pressurised metered-dose inhaler (pMDI) versus a newly developed hydrofluoroalkane(HFA)-propelled pMDI through various spacers. In addition, we aimed to study the effect on bronchodilator response when using an optimal pMDI/spacer combination for aerosol delivery compared to a suboptimal combination. METHODS: Particle size distribution and output from salbutamol pMDIs containing either CFC propellants (Ventolin) or HFA propellants (Airomir) were measured using a multistage liquid impinger (MSLI) and compared to that through both detergent-coated (non-static) or untreated (static) large volume (Nebuhaler, Volumatic) and small volume (Aerochamber) plastic spacers. Flow-volume curves (FEV1) were obtained from twelve asthmatic children with known significant bronchodilator response (8 males), aged 13-17 years, randomly inhaling salbutamol from a CFC-pMDI through a static spacer (Nebuhaler) and from an HFA-pMDI through a non-static spacer (Nebuhaler). RESULTS: In vitro output of particles in the respirable range (< 6.8 microns) from HFA-pMDIs was significantly higher than that from CFC-pMDIs using various spacers. Removal of electrostatic charge increased output from CFC- and HFA-pMDIs through all spacers by 17-82%. The mean (SD) bronchodilator response after inhalation of salbutamol from a CFC-pMDI through a static spacer was 7.1% (6.3%) compared to 17.5% (7.9%) after inhalation from an HFA-pMDI through a non-static spacer (p = 0.002). CONCLUSIONS: Use of a newly developed HFA-propelled pMDI greatly improves drug delivery through spacers compared to a CFC-propelled pMDI. However, electrostatic charge in plastic spacers remains the key determinant limiting delivery of salbutamol from a pMDI through spacers, and can be reduced by soaking the spacer in a household detergent. Using an optimal pMDI/spacer combination leads to a significantly improved bronchodilator response.
    [Abstract] [Full Text] [Related] [New Search]