These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Kinetic analysis of 125I-iodorotenone as a deposited myocardial flow tracer: comparison with 99mTc-sestamibi. Author: Marshall RC, Powers-Risius P, Reutter BW, Taylor SE, VanBrocklin HF, Huesman RH, Budinger TF. Journal: J Nucl Med; 2001 Feb; 42(2):272-81. PubMed ID: 11216526. Abstract: UNLABELLED: The goal of this investigation was to assess the accuracy of 7'-Z-[125I]iodorotenone (125I-iodorotenone) as a new deposited myocardial flow tracer and compare the results with those for 99mTc-sestamibi. METHODS: The kinetics of these two flow tracers were evaluated in 25 isolated, erythrocyte- and albumin-perfused rabbit hearts over a flow range relevant to patients. The two flow tracers and a vascular reference tracer (131I-albumin) were introduced simultaneously as a compact bolus through a port just above the aortic cannula in the absence of tracer recirculation. Myocardial extraction, retention, washout, and uptake parameters were computed from the venous outflow curves using the multiple-indicator dilution technique and spectral analysis. RESULTS: The extraction of 125I-iodorotenone was much higher than the extraction of 99mTc-sestamibi (0.84 +/- 0.05 vs. 0.48 +/- 0.10, respectively, P < 0.001). 125I-iodorotenone extraction was also less affected by flow than was 99mTc-sestamibi (P < 0.001). Net retention of 125I-iodorotenone was significantly greater than 99mTc-sestamibi net retention at 1 min (0.77 +/- 0.08 vs. 0.41 +/- 0.11, respectively, P < 0.001) and 26 min (0.46 +/- 0.13 vs. 0.27 +/- 0.11, respectively, P < 0.001) after tracer injection. Flow had less effect on 125I-iodorotenone net retention than on 99mTc-sestamibi net retention 1 min after tracer injection (P < 0.04). However, at 26 min, flow had an equivalent effect on the retention of both flow tracers (P < 0.4). The relationship between 125I-iodorotenone and 99mTc-sestamibi washout was complex and depended on elapsed time after isotope introduction and perfusion rate. Reflecting the favorable extraction and retention characteristics of 125I-iodorotenone, both its maximum myocardial uptake and its 26-min uptake were more closely related to flow than were those of 99mTc-sestamibi (P < 0.001 for both comparisons). CONCLUSION: The extraction and retention of 125I-iodorotenone were greater than those of 99mTc-sestamibi, making 125I-iodorotenone the superior flow tracer in the isolated rabbit heart.[Abstract] [Full Text] [Related] [New Search]