These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Morbidity and mortality associated with large-bore percutaneous venovenous bypass cannulation for 312 orthotopic liver transplantations.
    Author: Budd JM, Isaac JL, Bennett J, Freeman JW.
    Journal: Liver Transpl; 2001 Apr; 7(4):359-62. PubMed ID: 11303297.
    Abstract:
    The aim of this study is to establish the incidence of serious morbidity and mortality associated with the placement of large-bore (18 to 20 F) percutaneous bypass cannulae for venovenous bypass (VVBP) during orthotopic liver transplantation (OLT). This technique has been reported to be rapid, simple, and safe. We reviewed the case notes of 312 patients who underwent OLT in our center using this technique. We describe 4 cases of serious morbidity (incidence, 1.28%) and 1 death (incidence, 0.32%) related directly to percutaneous placement of the bypass cannula. We conclude that percutaneous cannula placement for VVBP during OLT has the potential for life-threatening complications, and this must be considered when electing to use this technique. When percutaneous cannulae are to be used, we recommend the use of the right internal jugular vein for return cannulation and the use of ultrasound guidance, particularly in those patients in whom cannulation is predictably difficult.