These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Indirect blood pressure measurement in the dog. Author: Garner HE, Hahn AW, Hartley JW, Hutcheson DP, Coffman JR. Journal: Lab Anim Sci; 1975 Apr; 25(2):197-202. PubMed ID: 1134034. Abstract: The validity of the ultrasonic Doppler technic for indirectly measuring arterial blood pressure over a wide range was tested in anesthetized dogs. Correlation coefficents of 0.99 and 0.97 for systolic and diastolic pressure were verified on the basis of 316 comparisons of direct and indirect measurements. Utility of the method for detecting hypotensive, normotensive, and hypertensive arterial blood pressures was demonstrated. Potential applications of the method by life scientists and veterinarians includes routine monitoring of anesthesia, characterization of disease, and documentation of pharmacologic states.[Abstract] [Full Text] [Related] [New Search]