These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Gas exchange and pulmonary mechanics under anaesthesia and artificial ventilation (author's transl)].
    Author: Voigt E, Weitzsäcker W.
    Journal: Anaesthesist; 1975 Apr; 24(4):166-70. PubMed ID: 1138563.
    Abstract:
    During general anaesthesia with controlled ventilation and normocapnia the A-a DO2 and pulmonary shunt were investigated in a group of 7 patients undergoing a parotidectomy or laryngectomy. In a second group of 21 patients the behaviour of the total, lung- and thorax compliance was investigated. Within the first 1 1/2 hours after induction of anesthesia the A-a DO2 and shunt increased. During the time the thorax compliance did not change, whereas the total and lung compliance decreased significantly. After 1 1/2 hours no further change occured.
    [Abstract] [Full Text] [Related] [New Search]