These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Rapid high-performance liquid chromatographic method for determination of doxycycline in human plasma. Author: Zarghi A, Kebriaeezadeh A, Ahmadkhaniha R. Journal: Boll Chim Farm; 2001; 140(2):112-4. PubMed ID: 11417385. Abstract: A simple, rapid and precise analytical method for determination of doxycycline in human plasma is described. A high-performance liquid chromatography (HPLC) system based on a mbondapak C18 column (300 mm x 4.6 mm i.d., 10 microns) and a UV detector (lambda = 347 nm) were used. A mixture of actonitrile 0.1 M potassium dihydrogen phosphate buffer (35:65 v/v) adjusted to pH 3 was used as mobile phase. The proteins were precipitated with a 24% perchloric acid aqueous solution. The detection limit for doxycycline in plasma was 3 ng mL-1. The average recovery was about 96%. The method is simple, sensitive and suitable for pharmacokinetic studies of doxycycline. The inter-day and intra-day assay coefficients of variation were found to be less than 8%.[Abstract] [Full Text] [Related] [New Search]