These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: WBC-reduced platelet concentrates from pooled buffy coats in additive solution: an evaluation of in vitro and in vivo measures.
    Author: van der Meer PF, Pietersz RN, Tiekstra MJ, Huijgens PC, Dekker WJ, Reesink HW.
    Journal: Transfusion; 2001 Jul; 41(7):917-22. PubMed ID: 11452160.
    Abstract:
    BACKGROUND: The use of a platelet additive solution (PAS-II, Baxter) may have benefits over plasma for storage of platelets. It was the aim of this study to develop a method to produce WBC-reduced platelet concentrates (PCs) in PAS-II with >240 x 10(9) platelets and <1 x 10(6) WBCs per unit, which can be stored for 5 days at pH >6.8 and that will give sufficient platelet increments after transfusion: a 1-hour CCI of >7.5 and a 20-hour CCI of >2.5. STUDY DESIGN AND METHODS: PCs were made from five pooled buffy coats and 250 g of PAS-II. After centrifugation the PCs were WBC-reduced with a filter (Autostop BC, Pall Biomedical) and stored in a 1000-mL polyolefin container. CCIs were assessed in stable hemato-oncologic patients after 5-day old PCs were transfused. RESULTS: Routinely produced PCs contained a median of 310 x 10(9) platelets (n = 5,363) with 3.5 percent containing <240 x 10(9) platelets, in a median volume of 320 mL (n = 11,834). The median number of WBCs was <0.03 x 10(6) (n = 694). The WBC count exceeded 1 x 10(6) in three PCs, but it was always <5 x 10(6), giving 99-percent confidence that more than 99.5 percent of the units will contain <1 x 10(6) WBCs. The pH remained >6.8 on Day 8, provided the concentration was below 1.1 x 10(9) platelets per mL (n = 32). After 28 transfusions in 28 patients, the 1-hour CCI was 12.6 +/- 4.3 (mean +/- SD, with 2/28 CCIs <7.5) and the 20-hour CCI was 8.9 +/- 5.6 (with 4/28 CCIs <2.5). Limitations of this study include the absence of a control group of patients receiving platelets stored in plasma and of in vivo radiolabeled survival studies, but a comparison of these data with previously published data suggested that the in vivo survival of platelets stored in PAS-II is less than that of platelets stored in plasma. CONCLUSION: The WBC-reduced PCs conformed to specifications. These WBC-reduced PCs could be stored at least 5 days with maintenance of pH, and they gave sufficient increments after transfusion to patients.
    [Abstract] [Full Text] [Related] [New Search]