These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Two evoked responses with different recovery functions in the primary somatosensory cortex in humans. Author: Hoshiyama M, Kakigi R. Journal: Clin Neurophysiol; 2001 Jul; 112(7):1334-42. PubMed ID: 11516746. Abstract: OBJECTIVES: We investigated the recovery function of somatosensory evoked magnetic cortical fields (SEFs) to confirm the temporal aspects of the somatosensory process in humans. METHODS: SEFs were recorded following median nerve electrical stimulation in 6 healthy subjects. Double stimulation, with interstimulus intervals (ISIs) from 3 to 100 ms, was applied, and the SEF components for the second stimulation were analyzed. In a supplementary experiment, responses to single stimulations of various intensities from the sensory threshold to the motor threshold were studied. RESULTS: The first SEF component (1M) diminished when the ISI was less than 10 ms, while the second component (2M) remained even when the ISI was 3 ms. The two components showed a very similar attenuation with decrease of stimulus intensity. There was no significant difference in dipole location between 1M and 2M in the primary somatosensory cortex (SI). CONCLUSIONS: The results suggested that at least two independent pathways with different recovery functions exist in a similar area in the SI.[Abstract] [Full Text] [Related] [New Search]