    We treated 11 patients with atlantoaxial instability using transarticular posterior screw fixation and lateral bone grafting. A posterior bone graft was added in eight patients. The results showed good reduction and a stable fixation. After 6 months ten patients had regained almost 70% of rotation and did not notice any significant limitation. Nous avons traité 11 patients pour instabilité atloïdo-axoïdienne utilisant une fixation par vis transarticulaire postérieure avec greffe osseuse latérale. Une greffe postérieure a été ajoutée chez huit patients. Les résultats ont montré bonne réduction et une fixation stable. Après 6 mois dix patients avaient regagné presque 70% de la rotation et ne se plaignaient pas de limitation notable.