Search MEDLINE/PubMed
Title: Micronuclei assay by laser scanning cytometry. Author: Smolewski P, Ruan Q, Vellon L, Darzynkiewicz Z. Journal: Cytometry; 2001 Sep 01; 45(1):19-26. PubMed ID: 11598943. Abstract: BACKGROUND: The micronuclei (MN) assay is used to assess the chromosomal/mitotic spindle damage induced by ionizing radiation or mutagenic agents in vivo or in vitro. Because visual scoring of MN is cumbersome semi-automatic procedures that relay either on flow cytometry or image analysis were developed: both offer some advantages but also have shortcomings. METHODS: In the present study laser scanning cytometer (LSC), the instrument that combines analytical capabilities of flow and image cytometry, has been adapted for quantitative analysis of MN. The micronucleation of human breast carcinoma MCF-7 and leukemic HL-60 and U-937 cells was induced by in vitro treatment with mitomycin C. Cellular DNA was stained with propidium iodide (PI), protein was counterstained with fluorescein isothiocyanate (FITC). Two approaches were used to detect MN: (a) the threshold contour was set based on the data from the photosensor measuring red fluorescence of PI and MN were identified on the bivariate PI versus PI/FITC fluorescence distributions by their characteristic position; (b) the threshold contour was set on the data from the sensor measuring FITC fluorescence which made it possible, using the LSC software dedicated for FISH analysis, to assay both the frequency and DNA content of individual MN within each measured cell. RESULTS: The capability of LSC to relocate MN for visual examination was useful to confirm their identification. Visual identification of MN combined with their multiparameter characterization that took into an account their DNA content and protein/DNA ratio made it possible establish the gating parameters that excluded objects that were not MN; 93.3+/-3.3 events within the selected gate were MN. It was also possible to successfully apply FISH software to characterize individual cells with respect to quantity of MN residing in them. The percentage of MN assayed by LSC correlated well with that estimated visually by microscopy, both for MCF-7 (r = 0.93) and HL-60 cells (r = 0.87). CONCLUSIONS: LSC can be used to obtain unbiased estimate of MN frequencies. Unlike flow cytometry, it also allows one to characterize individual cells with respect to frequency and DNA content of MN residing in these cells. These analytical capabilities of LSC may be helpful not only to score MN but also to study mechanisms by which clastogenic agents induce MN.[Abstract] [Full Text] [Related] [New Search]