These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Determination of flavonoids and stilbenes in red wine and related biological products by HPLC and HPLC-ESI-MS-MS. Author: Stecher G, Huck CW, Popp M, Bonn GK. Journal: Fresenius J Anal Chem; 2001 Sep; 371(1):73-80. PubMed ID: 11605763. Abstract: To investigate probable health benefits of flavonoids and stilbenes in red wine a new reversed-phase (RP) high-performance liquid-chromatographic (HPLC) method with enhanced separation efficiency and improved selectivity, sensitivity, and speed has been established for determination of the flavonoids quercetin, myricetin and kaempferol and the stilbenes cis- and trans-resveratrol, in a single run . UV-absorbance, fluorescence (FLD), and mass-spectrometric (MS) detection were also evaluated. UV-absorbance detection at 320 nm for stilbenes and 377 nm for flavonoids enables their determination up to the nanogram range with a linearity of R2>0.9999 (linear range 50 ng mL(-1)-50 microg mL(-1)). Calculated values of average recoveries were between 95 and 105% for all analytes. For resveratrol, fluorescence detection was highly selective and twice as sensitive as UV detection, and linearity was satisfactory (R2>0.9996; linear range see UV detection). For the detection of the hydrophilic glycosidic compounds piceid and rutin, which are coeluted with other hydrophilic ingredients, the validated RP HPLC system was coupled to a quadrupole ion-trap mass-spectrometer (MS) via an electrospray interface (ESI) with 25% ammonia solution as sheath liquid. MS detection was, highly linear (R2>0.9878; linear range 50 ng mL(-1)-50 microg mL(-1)) for all investigated analytes and the limits of detection were in the low nanogram range. Compared with UV detection MS detection resulted in a 200% increase in signal intensity for myricetin and 400% increases for quercetin and kaempferol, but equal signal intensity for resveratrol. Calculated values of average recoveries were 102% for myricetin and 79% for piceid. Collision induced dissociation (CID) was also used to obtain characteristic fragmentation fingerprints to facilitate qualitative and quantitative analysis even in complex matrices. Finally, this hyphenated HPLC-ESI-MS method was highly suitable and an essential improvement compared with UV- and fluorescence detection.[Abstract] [Full Text] [Related] [New Search]