These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Occlusion of carotid-cavernous fistula with a balloon catheter.
    Author: Bahuleyan K, Nelson LR, Peck FC.
    Journal: Surg Neurol; 1975 Jun; 3(6):283-7. PubMed ID: 1162578.
    Abstract:
    Occlusion of a carotid-cavernous fistula with a balloon catheter appears to be easier and perhaps safer than the widely used trapping procedure. Two cases successfully treated using this technique are reported along with a discussion of the advantages, disadvantages, and possible future improvements in technique.
    [Abstract] [Full Text] [Related] [New Search]