These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Determination of hydroxyalkyl derivatives of cobalamin (vitamin B12) using reversed phase high performance liquid chromatography with electrospray tandem mass spectrometry and ultraviolet diode array detection. Author: Alsberg T, Minten J, Haglund J, Törnqvist M. Journal: Rapid Commun Mass Spectrom; 2001; 15(24):2438-45. PubMed ID: 11746915. Abstract: Electrospray ionization tandem mass spectrometry (ESI-MS/MS) and ultraviolet diode array detection (UV-DAD), coupled on-line to reversed phase high performance liquid chromatography (HPLC), was used for the characterization of hydroxyalkyl derivatives of cob(I)alamin. The reduced form of vitamin B12, cob(I)alamin, denoted a supernucleophile due to its high nucleophilic strength, has shown promise as an analytical tool in studies of electrophilically reactive compounds in vitro and in vivo. A method for analysis of DNA-phosphate adducts was developed earlier utilizing the supernucleophilicity of cob(I)alamin to transfer alkyl groups from the phosphotriester configuration in DNA, with the formation of a Co-substituted alkyl-cobalamin (alkyl-Cbl) complex. For the purpose of identification and quantification of alkyl-Cbls at high sensitivity, an MS/MS method has been developed with application to a number of 2-hydroxyalkyl-cobalamins (OHalkyl-Cbls). The precursor oxiranes were reacted with cob(I)alamin, followed by clean-up and mass spectrometric analysis of the resulting OHalkyl-Cbls. It was found that ionization was highly dependent on solvent composition. By using acetonitrile/water/trifluoroacetic acid (TFA) (eluent I), the base peak was the doubly protonated molecule [M + 2H](2+), whereas acetonitrile/water/1-methylpiperidine (eluent II) yielded the singly protonated molecule [M + H](+) as the base peak. Excellent separation was obtained with eluent II, with good separation between stereoisomers, thus enabling the characterization of these by means of UV spectra. Limits of quantitation for 2-hydroxypropyl-cobalamin (OHPr-Cbl) were 0.2 and 2 pg/microL (or 0.1 and 1 fmol/microL) using selected ion recording (SIR) with eluent I and II, respectively. The obtained detection level should be sufficient for analysis of alkyl-Cbls from a wide range of toxicological applications.[Abstract] [Full Text] [Related] [New Search]