These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Emergency ventricular assist device: better survival rates in non-post cardiotomy-related cardiogenic shock.
    Author: Rodrigus IE, Amsel BJ, Conraads V, De Hert S, Moulijn AC.
    Journal: Acta Chir Belg; 2001; 101(5):226-31. PubMed ID: 11758106.
    Abstract:
    OBJECTIVE: The Abiomed BVS 5000 ventricular assist device (VAD) has been approved in Belgium for emergency cardiac support in patients with postcardiotomy failure with the aim of native heart function recovery. Other indications have emerged from world wide experience, but the indication and usefulness of emergency implantation of assist devices is often debated. METHODS: To decide which patients benefit most from emergency ventricular assist device implantation, we retrospectively reviewed our results of mechanical circulatory support with Abiomed in 20 patients over a 4-year period. Fifteen patients with mean age 58 +/- 6 years experienced postcardiotomy failure and underwent biventricular assist device (BVAD) implantation (group A), after elective (n = 9) or after emergency coronary artery bypass grafting (CABG) (n = 6). Five patients (group B), with mean age 35 +/- 19 years, had an implantation for other underlying conditions: hypertrophic cardiomyopathy (n = 3), myocarditis (n = 1) and primary cardiac allograft failure (n = 1). RESULTS: Of these two groups, eight and two patients respectively needed cardiopulmonary resuscitation before VAD implantation. The mean duration of support in both groups was 5.8 (range 12 h-13 days) and 4.4 days (range 2 h-9 days) respectively. Six and two patients could be weaned from the device and nine and one patients respectively, died on the device. Two patients in group B underwent successful heart transplantation and four patients in group A died after weaning. Two patients in the postcardiotomy group and four patients in group B survived (13% and 80%) with an overall survival and discharge rate of 30%. CONCLUSION: Although sample sizes are small, better survival rates with emergency Abiomed BVS 5000 implantation were obtained in the non postcardiotomy group (group B). For patients in the postcardiotomy group, outcome was negatively influenced by cardiac arrest and resuscitation before urgent CABG. Since death is the only alternative for these patients in cardiogenic shock and organ recovery cannot be predicted, we continue to consider emergency VAD implantation in this patient population.
    [Abstract] [Full Text] [Related] [New Search]