These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: [MR myelography: analysis of 126 cases]. Author: Wang W, Zhang X, Lu Y. Journal: Zhonghua Yi Xue Za Zhi; 2000 Mar; 80(3):183-6. PubMed ID: 11798754. Abstract: OBJECTIVE: To investigate the value and limitation of MR myelography (MRM) in depicting the spinal canal obstruction. METHODS: Heavily T2-weighted coronal MR myelography was performed with 3D fast-spin-echo (FSE) and fat-suppression sequence in 126 cases, including 6 cerebellomedullary cistern, 18 cervical, 19 thoracic and 83 lumbar cases. The resulting slice were then projected into a composite image using a standard maxium intensity projection (MIP) algorithm. RESULTS: 90.5% (114/126) of MRM yielded reproducible high-quality image of the spinal thecal sac. 106 lesions (extradural, intradural, intramedullary) were detected in 101 cases (80.2%). The level and degree of spinal canal obstruction were visualized and confirmed by operation in 66 cases with a high sensitivity of 100%, and a diagnostic accuracy of 91.3%. CONCLUSION: Heavily T2 FSE MR myelography is a noninvasive and reliable method. MRM surpasses conventional and CT myelography and could replace them in some degree.[Abstract] [Full Text] [Related] [New Search]