These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Angiographic outcome after intracoronary X-Sizer helical atherectomy and thrombectomy: first use in humans. Author: Kwok OH, Prpic R, Gaspar J, Mathey DG, Escobar A, Goldar-Najafi A, Reifart N, Ischinger TA, Popma JJ. Journal: Catheter Cardiovasc Interv; 2002 Feb; 55(2):133-9. PubMed ID: 11835634. Abstract: The objective of this study was to evaluate the early angiographic outcome in the first human subjects who underwent intracoronary atherectomy and thrombectomy using the X-Sizer helical cutting and aspiration system. Percutaneous coronary interventions in patients with thrombo-occlusive disease or friable degenerative saphenous vein grafts are associated with considerable periprocedural morbidity and mortality, predominantly related to microscopic distal embolization. X-Sizer catheter system is a novel atherectomy and thrombectomy device that consists of a helix cutter connected to a handheld motor drive unit and a vacuum collection chamber for aspiration of excised atheroma, thrombus, and debris. Quantitative coronary angiography was obtained in 14 patients before and after X-Sizer extraction atherectomy with adjunctive balloon angioplasty and stenting. Thirteen native coronary arteries and one saphenous vein graft were treated. Mean preprocedural reference vessel diameter was 3.06 +/- 0.66 mm. There were 71.4% AHA/ACC type B2 and C lesions. Preprocedural thrombus was present in nine patients and total occlusion in 64% of cases. Minimal luminal diameter was increased from 0.29 +/- 0.47 mm to 1.32 +/- 0.64 mm, a gain of 1.04 +/- 0.69 mm after atherectomy. Final total gain was 1.47 +/- 0.61 mm. Mean diameter stenosis was reduced from 89.3% to a final residual stenosis of 14.4%. Postatherectomy distal embolization occurred in one patient who had heavy preprocedural thrombus burden. No episodes of perforation, distal coronary spasm, abrupt closure, or slow/no-reflow occurred. The angiographic analysis of the first cohort of human subjects suggests that X-Sizer helical atherectomy is a feasible method of removing occlusive tissue or thrombus in coronary artery disease with a low angiographic complication rate. A large-scale randomized phase II clinical trial is underway to determine the ultimate safety and efficacy of this device in thrombo-occlusive native coronary arteries and saphenous vein grafts.[Abstract] [Full Text] [Related] [New Search]