  • Title: [Removal of polyps from the stomach and large intestine through a fiberscope].
    Author: Savel'ev VS, Buianov VM, Kornilov IuM, Balalykin AS.
    Journal: Vestn Khir Im I I Grek; 1975 Feb; 114(2):26-31. PubMed ID: 1189210.
    Abstract:
    Polypectomy was performed with a special device (a loop and scissors) inserted via the biopsy canal of a fibroscope. During polypectomy diathermic currents from a commerical electric knife are used. An experience with 67 polypectomies has shown that this operation requirs no special pre- and postoperative measures. Failures of polypectomy were as follows: inadequate polypectomy and development of pseudorecurrences, "a loss" of a polyp during its removal, an impossibility ot loop a polyp. Complications that may appear are described.