Search MEDLINE/PubMed
Title: Simultaneous determination of eleven benzodiazepine hypnotics and eleven relevant metabolites in urine by column-switching liquid chromatography-mass spectrometry. Author: Miki A, Tatsuno M, Katagi M, Nishikawa M, Tsuchihashi H. Journal: J Anal Toxicol; 2002 Mar; 26(2):87-93. PubMed ID: 11916020. Abstract: An automated column-switching liquid chromatographic-atmospheric pressure chemical ionization-mass spectrometric (LC-APCI-MS) method for the simultaneous determination of frequently encountered benzodiazepine hypnotics and their relevant metabolites in urine has been established. A column-switching online solid-phase extraction technique was employed to enhance sensitivity and eliminate tedious sample pretreatment. The combination of an N-vinylacetamide-containing hydrophilic polymer online extraction column and a C18 semi-micro LC column provided the successful separations and MS determinations of the 11 benzodiazepines and 11 relevant metabolites tested in this study. The detection limits ranged 2-10 ng/mL and 10-50 ng/mL in the SIM and full-scan modes, respectively, using 50 microL of urine. The calibration curves were linear up to 500 ng/mL for all these analytes in the SIM mode. The present method provided successful forensic applications for the proof of benzodiazepine administration.[Abstract] [Full Text] [Related] [New Search]