These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Efficacy and safety of a 7.5% icodextrin peritoneal dialysis solution in patients treated with automated peritoneal dialysis. Author: Plum J, Gentile S, Verger C, Brunkhorst R, Bahner U, Faller B, Peeters J, Freida P, Struijk DG, Krediet RT, Grabensee B, Tranaeus A, Filho JC. Journal: Am J Kidney Dis; 2002 Apr; 39(4):862-71. PubMed ID: 11920355. Abstract: In a randomized, prospective, multicenter study, we compared the safety, efficacy, and metabolic effects of a 7.5% icodextrin solution (Extraneal) with a 2.27% glucose solution for long dwell exchanges in patients undergoing automated peritoneal dialysis. Thirty-nine stable patients on automated peritoneal dialysis were randomized to receive either icodextrin (n = 20) or glucose 2.27% solution (n = 19). The study included a 2-week baseline period followed by a 12-week icodextrin treatment phase and a 2-week follow-up period when switching back to glucose. The average net ultrafiltration during the long dwell period was 278 +/- 43 mL/d for the icodextrin group and -138 +/- 81 mL/d for the control group (P < 0.001). The higher ultrafiltration volume with icodextrin was associated with higher creatinine (2.59 +/- 0.09 mL/min versus 2.16 +/- 0.11 mL/min) and urea (2.67 +/- 0.09 mL/min versus 2.28 +/- 0.12 mL/min) peritoneal clearances for the long dwell (both P < 0.001). Ultrafiltration rate per mass of carbohydrate absorbed was +5.2 +/- 1.2 microL/min/g in the icodextrin group and -5.5 +/- 2.8 microL/min/g in the glucose group (P < 0.001). In the icodextrin group, there was a decrease in serum sodium and chloride compared with baseline (P < 0.01). Total dialysate sodium removal increased in the icodextrin group from 226.7 mEq to 269.6 mEq (week 12, P < 0.001). Serum alpha-amylase activity decreased from 103 U/L to 16 U/L (P < 0.001). The total icodextrin plasma levels reached a steady-state concentration of 6,187 +/- 399 mg/L after 1 week of treatment. Urine volume and residual renal function were not specifically affected by icodextrin compared with glucose. None of the laboratory changes resulted in any reported clinically meaningful side effect. Icodextrin produced increased, sustained ultrafiltration during the long dwell period, increasing (convective) peritoneal clearance and sodium removal in automated peritoneal dialysis patients.[Abstract] [Full Text] [Related] [New Search]