These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Evaluation of a new combined antigen and antibody human immunodeficiency virus screening assay, VIDAS HIV DUO Ultra. Author: Weber B, Berger A, Rabenau H, Doerr HW. Journal: J Clin Microbiol; 2002 Apr; 40(4):1420-6. PubMed ID: 11923367. Abstract: Combined antigen and antibody screening (fourth-generation) assays reduce the diagnostic window period between the time of human immunodeficiency virus (HIV) infection and laboratory diagnosis by 4 days, on average, in comparison to antibody-only (third generation) enzyme immunoassays (EIAs). The aim of the present study was to assess whether the new VIDAS HIV DUO Ultra (Biomérieux, Marcy-l'Etoile, France) showed an improved sensitivity and specificity in comparison to licensed fourth-generation assays. A total of 16 seroconversion panels, 15 cell culture supernatants infected with different HIV type 1 (HIV-1) subtypes, and 257 potentially cross-reactive serum samples were tested with VIDAS DUO HIV Ultra, Genscreen Plus HIV Ag-Ab, Enzygnost HIV Integral, Enzymun-Test HIV Combi, Genscreen HIV 1/2, version 2 (third-generation EIA), and Genetic Systems HIV-1 Ag EIA (p24 antigen assay). VIDAS HIV DUO Ultra showed a comparable sensitivity to the single p24 antigen assay in seroconversion panels and a dilution series of virus lysates. The diagnostic window was reduced with VIDAS HIV DUO Ultra by 3.82 days, on average, in comparison with the fourth-generation assay with the lowest sensitivity of the antigen detection module. HIV-1 infection was detected 5.88 days earlier than with third-generation EIA. The mean time delay between reverse transcription-PCR and VIDAS HIV DUO Ultra was only 2.31 days. The specificity of fourth-generation assays after retesting ranged between 98.1 and 100%. In conclusion, VIDAS HIV DUO Ultra can replace single-antigen screening for laboratory diagnosis and screening of HIV infection in blood donors. There was no evidence for a second diagnostic window due to impaired sensitivity of the antibody detection module of all the fourth-generation EIAs evaluated in the present study. The specificity after initial and/or repeated testing of VIDAS HIV DUO Ultra was equivalent to that of a third-generation assay.[Abstract] [Full Text] [Related] [New Search]